Streamline® Closed Restricted Access Barrier System

Streamline® Closed Restricted Access Barrier System
  • ULPA filters (as per IEST-RP-CC001.3 and HEPA (H14) filter as per EN 1822) with a typical efficiency of >99.995% at 0.1 to 0.3 microns, providing ISO Class 5 air cleanliness as per ISO 14644-1.
  • Sentinel™ Gold Microprocessor controller supervises all functions and monitors airflow and pressures in real-time.
  • For negatively pressured RABS, the work zone and pass-through chambers are under negative pressure to the room to maintain operator protection in the event of a breach in the system.
  • Positively pressured configurations are under positive pressure to the room to ensure product protection.
  • Robust dual-wall construction. The work zone is surrounded by negative pressure plenums at the sides and back. Unique Esco Dynamic Chamber™ plenum surrounds filter seals with negative pressure.
  • Ergonomically angled front and oval gloveports improve reach and comfort.
  • Safe-change cuff rings permit glove changing with zero risk of contaminating the work zone and/or pharmacy environment.
  • Esco ISOCIDE™ antimicrobial coating on all painted surfaces to minimize contamination.
  • Sharps disposal system and hydraulic height adjustable stand are available as options.

Streamline® Closed - Restricted Access Barrier System

SLC-RABS-4CN3-S

Sharps Provision

Pressure Scheme

Electrical Code

Glove Port Design

Nominal Width

Model

Unit

No

0

Negative

N

220-240 V, AC, 50 Hz, 1Ø

1

Circular glove port

(300 mm x 300 mm)

C

4 ft (1.2 m)

4

SLC-RABS

Streamline® Closed - Restricted Access Barrier System

110-120 V, AC, 50 Hz,

2

Yes

S

Positive

P

Oval glove port

(200 mm x 300 mm)

O

6 ft (1.8 m )

6

220-240 V, AC, 60 Hz, 1Ø

3

Standard Accessories

  • Airlock pass-through
  • Vertical pass-through door
  • Horizontal tray for easy material transfer

Electrical Outlets and Utility Fittings

  • Electrical outlet, ground fault, North America
  • Electrical outlet, Euro/Worldwide

Support Stands

  • Fixed height, available 711 mm (28") or 864 mm (34") - With levelling feet, ± 38.1 mm (1.5") (SAL) - With casters (SPC)
  • Telescoping height stand for levelling feet (STL), nominal range 660 mm to 960 mm (26"to 37.8")
  • Telescoping height stand for casters (STC), nominal range 660 mm to 880 mm (26" to 34.6") - Adjustable in 25.4 mm (1") increments
  • Infinitely adjustable hydraulic stand with casters elevates to accommodate a sitting or a standing user's work surface height (SHM)

Options

  • Electrical outlets
  • UV lamp
    *Note: Clearly indicate in PO as UV lamp for SLC-RABS is factory-installed.
  • Sharps disposal system
  • Alarm package
  • Exhaust carbon filter
  • Thimble exhaust collar
  • Perforated shelf to increase work zone space